Package Include:
1 x Receiver: S2PU-DC-ANT3
2 x Transmitters: C-2/C-3
1 x User manual
Application:
This is a wireless remote switch kit with 2 channel relay output. It including a S2PU-DC-ANT3 receiver and two C-2 / C-3 transmitters. It may be used in all types of industry automation, agriculture, business, home, factory, house, farm, garage, vehicle, ship, aerial vehicle, etc. It can remote control different DC or AC equipment on land, water, and air, such as lights, doors, windows, lamps, sockets, locks, sirens, outlets, heaters, motors, fans, winches, curtains, blinds, linear actuators, electric solenoid valves, and security alarm systems. The applications are endless.
Key Features:
Wireless control, easy to install.
Waterproof Design: Receiver has waterproof case and waterproof connector for outdoor use.
DC 10~80V operating voltage range.
Relay Output: This receiver is dry relay output; it can be used to operate both DC and AC equipment.
High Power: Each channel can work at maximum current 30A.
4 Selectable Working Modes: Self-locking, Momentary, Interlocking, Momentary + Self-locking.
With external antenna, the receiver has a farther working range.
Reliable Signal: RF signal can pass through walls, floors, doors, or windows, but it will lose some operating range.
Safety Features: Reverse voltage and overcurrent protection.
Interference: Two or more receivers may be used in the same area without interference.
One or more transmitters / remotes can control one or several receivers simultaneously.
Receiver S2PU-DC-ANT3 Parameters:
| Parameters | Detail |
|---|---|
| Operating Voltage Options | 10~80V DC |
| Output Type | Relay Output (With NO and NC Terminals) |
| Channel | 2 CH |
| Working Frequency | 433.92MHz |
| Load Capacity | 240VAC or 28VDC, Max 30A/channel |
| 4 Selectable Working Modes | Self-locking, Momentary, Interlocking, Momentary + Self-locking |
| Suitable Wires for Connecting Terminals | 22-12 AWG |
| Operating Temperature | -20 °C ~ +70 °C |
| PCB size | 88 x 80 x 18 mm (3.5 x 3.1 x 0.7 inches) |
| Case size | 153 x 90 x 55 mm (6.0 x 3.6 x 2.2 inches) |
| Matching Transmitters | Can work with different transmitters, such as model C-2 / C-3 (100M), CWB-2 / CWB-3 (50M, waterproof), CP-2 / CP-3 (500M) and CB-2 / CB-3 (1000M) etc. |
Transmitter C-2 (2 Buttons) / C-3 (3 Buttons) Parameters:
| Parameters | Detail |
|---|---|
| Operating Voltage | 12V (1 x 23A -12V battery, can be used for 12 months) |
| Button Symbol | A, B (C-2) / A, B, C (C-3) |
| Operating Frequency | 433.92Mhz |
| Encoding Chip | PT2262 / PT2264 / SC2262 |
| Transmitting Distance | 100m / 300ft (theoretically) |
| Unit Size | 58 x 39 x 16 mm (2.3 x 1.5 x 0.6 inches) |
Wiring:
1) If you want to control a DC 12V lamp, do as following:
1.1 Connect the positive pole of DC power supply to terminal <+>, and connect the negative pole of DC power supply to terminal <->.
1.2 Connect terminal <NO> to the positive pole of DC power supply, connect terminal <COM> to the positive pole of DC lamp, and connect the negative pole of DC lamp to the negative pole of DC power supply.
2) If you want to control an AC 120V lamp, do as following:
2.1 Connect the positive pole of DC power supply to terminal <+>, and connect the negative pole of DC power supply to terminal <->.
2.2 Connect terminal <NO> to the live wire of AC power supply, connect terminal <COM> to one side of AC lamp, and connect another side of AC lamp to the neutral wire of AC power supply.
Setting different control modes:
The receiver will be set in Self-locking mode before leaving the factory, if you want to use another mode, please follow the following steps.
1) Setting Momentary mode: Press the learning button in the receiver 2 times, signal LED continuously flashes 2 times and then goes off.
Operation with C-2:
Hold button A → Relay 1 of the receiver activated (device 1 ON)
Release button A → Relay 1 of the receiver deactivated (device 1 OFF)
Hold button B → Relay 2 of the receiver activated (device 2 ON)
Release button B → Relay 2 of the receiver deactivated (device 2 OFF)
2) Setting Self-locking mode: Press the learning button in the receiver 3 times, signal LED continuously flashes 3 times and then goes off.
Operation with C-2:
Press button A → Relay 1 of the receiver activated (device 1 ON)
Press button A again → Relay 1 of the receiver deactivated (device 1 OFF)
Press button B → Relay 2 of the receiver activated (device 2 ON)
Press button B again → Relay 2 of the receiver deactivated (device 2 OFF)
3) Setting Interlocking mode: Press the learning button in the receiver 4 times, signal LED continuously flashes 4 times and then goes off.
Operation with C-3:
Press button A → Relay 1 of the receiver activated (device 1 ON); Relay 2 of the receiver deactivated (device 2 OFF)
Press button B → Relay 2 of the receiver activated (device 2 ON); Relay 1 of the receiver deactivated (device 1 OFF)
Press button C → Relay 1 and 2 of the receiver deactivated (device 1 and 2 OFF)
4) Setting Momentary (Channel 1) + Self-locking (Channel 2) mode: Press the learning button in the receiver 5 times, signal LED continuously flashes 5 times and then goes off.