Package Include:
1 x Manual Switch
1 x User Manual
Introduction:
This manual switch has two pushbuttons UP and DOWN. Each button has a set of normally open contacts. You can connect this manual switch to wired control terminals of the receiver, or connect to manual switch terminals of linear actuator synchronization controller, and then use it to control the DC motor or the linear actuator.
Product Description:
| Parameters | Detail |
|---|---|
| Two buttons | UP, DOWN |
| Work Mode | Momentary |
| Button diameter | 30 MM |
| Hole diameter | 22 MM |
| Contact Material | Silver Contacts |
| Contact rated current | 10A |
| Operating Temperature | -20°C to +70°C |
| IP rating | IP65 |
| Case size | 105 x 68 x 50 mm (4.1 x 2.7 x 2.0 inches) |
| Each button is equipped with a set NO contacts | |
| Waterproof case and waterproof connector | |
| Impact-resistant plastic case | |
| Suitable for our receivers with wired control terminals, such as model S1FC-DC, S1PF-DC, S1PF3-DC, S1F2-DC, S1FC-AC, and S1F2-AC | |
| Suitable for our linear actuator synchronization controllers with manual switch terminals | |
Wiring:
Connect to the receiver S1FC-DC:
1. Connect the positive pole of DC power supply to terminal <+> of the receiver's input, and connect the negative pole of DC power supply to terminal <-> of the receiver's input.
2. Connect the manual switch to the receiver's wired control terminals as follows:
1) Terminal 3 of UP button to <UP> terminal
2) Terminal 3 of DOWN button to <DOWN> terminal
3) Terminal 4 of both the UP and DOWN buttons to <COM> terminal
3. Connect two wires of the motor or the linear actuator to terminals <Motor> of the receiver, and you can exchange these two wires to change the rotating direction of the motor or the moving direction of the linear actuator.
Connect to the receiver S1PF-DC:
1. Connect the positive pole of DC power supply to terminal <+> of the receiver's input, and connect the negative pole of DC power supply to terminal <-> of the receiver's input.
2. Connect the manual switch to the receiver's wired control terminals as follows:
1) Terminal 3 of UP button to <S1> terminal
2) Terminal 3 of DOWN button to <S2> terminal
3) Terminal 4 of both the UP and DOWN buttons to <GND> terminal
3. Connect two wires of the motor or the linear actuator to terminals <Motor> of the receiver, and you can exchange these two wires to change the rotating direction of the motor or the moving direction of the linear actuator.
Connect to the synchronization controller with manual switch function:
1. Connect the positive pole of DC power supply to the terminal <+> of the controller, and connect the negative pole of DC power supply to the terminal <-> of the controller.
2. Connect the manual switch to the controller's manual switch terminals as follows:
1) Terminal 3 of UP button to <UP> terminal
2) Terminal 3 of DOWN button to <DN> terminal
3) Terminal 4 of both the UP and DOWN buttons to <COM> terminal
3. Plug the linear actuators into into the corresponding channel terminal of the controller.
Operation:
1) Press and hold the UP button, motor rotates in positive direction, or linear actuator extends outward; Release the button, motor or linear actuator stops.
2) Press and hold the DOWN button, motor rotates in reversal direction, or linear actuator inward retracts; Release the button, motor or linear actuator stops.